Description
WHFITFC process filter housings are designed for applications in process industry, where the risk for corrosion of compressed air system components is very high. WHFITFC process filter housing can be used in variety of applications. For applications not listed please contact producer or your local distributor. For oil removal, coalescing filter element must be installed and flow direction inside-out must be provided. General arrangement is filter head on top and filter bowl on bottom. Required compressed air quality according to standard ISO 8571-1 can be achieved with 8 different grades of filter elements (PI, PIW, PN, PP, PR, PM, PS and PA).
Operating Pressure: 50 bar
Technical Data:
Filter Housing Size |
Pipe Size | Max. Oper. Pressure | Flow Rate at 7 bar(g), 20ºC |
Dimensions (mm) |
Mass | ||||
inch | bar/psi | Nm³/h | scfm | A | B | C | D | Kg | |
WHFITFC 010 | 1/2’’ | 50/725 | 150 | 88 | 231 | 125 | 76.1 | 1/2’’ | 2.5 |
WHFITFC 018 | 3/4’’ | 50/725 | 225 | 132 | 253 | 125 | 76.1 | 1/2’’ | 2.6 |
WHFITFC 030 | 1’’ | 50/725 | 315 | 185 | 274 | 136 | 88.9 | 1/2’’ | 3.4 |
WHFITFC 047 | 1 1/4’’ | 50/725 | 420 | 247 | 336 | 155 | 88.9 | 1/2’’ | 3.9 |
WHFITFC 070 | 1 1/2’’ | 50/725 | 600 | 353 | 387 | 180 | 114.3 | 1/2’’ | 5.6 |
WHFITFC 094 | 2’’ | 50/725 | 900 | 530 | 453 | 180 | 114.3 | 1/2’’ | 6.2 |
WHFITFC 150 | 2’’ | 50/725 | 1260 | 742 | 580 | 180 | 114.3 | 1/2’’ | 6.9 |
WHFITFC 200 | 3’’ | 50/725 | 2400 | 1413 | 1005 | 224 | 139.7 | 1/2’’ | 14.1 |
Correction Factors:
Operating pressure [bar] | 7 | 20 | 30 | 40 | 50 |
Operating pressure [psi] | 100 | 290 | 435 | 580 | 725 |
Correction factor | 1 | 2.63 | 3.88 | 5.13 | 6.38 |
Filter Elements:
Filter Element Type |
Flow Rate | Filter Housing |
Nm³/h | ||
0420 | 150 | WHFITFC 010 |
0520 | 225 | WHFITFC 018 |
0525 | 315 | WHFITFC 030 |
0725 | 420 | WHFITFC 047 |
0730 | 600 | WHFITFC 070 |
1030 | 900 | WHFITFC 094 |
1530 | 1260 | WHFITFC 150 |
3030 | 2,400 | WHFITFC 200 |
Differential Pressure Indicator:
Accessories: